| Code |
Description |
| 00 |
Test full LCD display |
| 01 |
Test relay |
| 02 |
Test buzzer |
| 03 |
Total kWh register |
| 04 |
Display key revision number & type |
| 05 |
Display tariff index |
| 06 |
Reserved |
| 07 |
Display power limit (kW) |
| 08 |
Display tamper status |
| 09 |
Display power consumption |
| 10 |
Display software version |
| 11 |
Display phase power unbalance limit |
| 12-36 |
Belum ditentukan |
| 37 |
Credit balance(kWh) |
| 38 |
Stand kumulatif(kWh)phase R per bulan |
| 39 |
Stand kumulatif(kWh)phase S per bulan |
| 40 |
Stand kumulatif(kWh)phase T per bulan |
| 41 |
Tegangan fase R (V) |
| 42 |
Tegangan fase S (V) |
| 43 |
Tegangan fase T (V) |
| 44 |
Arus fase R (A) |
| 45 |
Arus fase S (A) |
| 46 |
Arus fase T (A) |
| 47 |
Arus Netral (A) |
| 48 |
Daya fase R (W) |
| 49 |
Daya fase S (W) |
| 50 |
Daya fase T (W) |
| 51 |
Total kVARh |
| 52 |
kWh total Berjalan |
| 53 |
Total token credit diterima |
| 54 |
credit token terakhir diterima |
| 55 |
ke 2nd terakhir credit token diterima |
| 56 |
ke 3rd terakhir credit token diterima |
| 57 |
ke 4th terakhir credit token diterima |
| 58 |
ke 5th terakhir credit token diterima |
| 59 |
Nilai credit kWh terakhir diterima |
| 60 |
Nilai 2nd credit kWh terakhir diterima |
| 61 |
Nilai 3rd credit kWh terakhir diterima |
| 62 |
Nilai 4th credit kWh terakhir diterima |
| 63 |
Nilai 5th credit kWh terakhir diterima |
| 64 |
Total technical token telah diterima |
| 65 |
terakhir technical token diterima |
| 66 |
Terakhir Ke 2nd
technical token diterima |
| 67 |
terakhir ke 3rd technical token diterima |
| 68 |
Total trip karena beban lebih |
| 69 |
Total meter off |
| 70 |
Total pembukaan terminal cover |
| 71 |
Total pembukaan meter cover |
| 72 |
Total tampering |
| 73 |
Energy consumption negative (-) credit |
| 74 |
Hardware version |
| 75 |
No.ID meter |
| 76 |
Meter constant |
| 77 |
Supply group code(SGC) |
| 78 |
Nilai seting durasi
Alarm |
| 79 |
Nilai seting Limit credit alarm |
| 80 |
Total power factor |
| 81 |
kWh total fase R per bulan |
| 82 |
kWh total phase S per bulan |
| 83 |
kWh total phase T per bulan |
| 84 |
THD Arus dan Tegangan |
| 85 |
Perkiraan waktu credit akan habis |
| 86 |
Informasi tamper terakhir |
| 87 |
kWh total bulan lalu |
| 88 |
kWh total 2 bulan lalu |
| 89 |
kWh total 3 bulan lalu |
| 90 |
Kejadian overload terakhir(waktu) |
| 91 |
Terakhir meter padam(waktu) |
| 92 |
Terakhir pembukaan cover/terminal |
| 93 |
Nilai maximum power bulan ini |
| 94 |
Waktu terjadi maximum power bulan ini |
| 95 |
Jam |
| 96 |
Tanggal |
| 97 |
Belum ditentukan |
| 98 |
Informasi pengukuran 3 fase |
| 99 |
Checksum software |
| 123xxx |
Buzzer durasi setting |
| 456xx |
Low credit limit setting |
| 147 |
Nilai factor setting
fk1 |
| 159 |
Nilai factor setting
fk2 |
|
|
|
Tampering status (08) |
| 1 |
Open terminal cover keadaan bertegangan |
| 2 |
Open terminal cover keadaan tidak bertegangan |
| 3 |
Reverse power (arus terbalik arah) dan (polaritas tegangan
sesuai) |
| 4 |
Hubung singkat (Bypass) |
| 5 |
Kabel fasa atau netral diberi injeksi |
| 6 |
Kabel netral tidak terpasang |
| 7 |
Kabel netral tidak terpasang dan dipasang voltage regulator di
sisi pelanggan |
| 8 |
Pengaruh medan magnetic (400mT) |
| 9 |
Hilang satu atau lebih fasa |
| 10 |
Arus tidak seimbang dengan sudut fasa diatas 90ยบ |